Analog Laser Power Probe Statistics

Analog Laser Power Probes, Analog Laser Measure - Measuring Laser Performance

Model

Power Range

Wavelength

Damage
Threshold
(at max
Power)

Exposure Time

Watts/
Division

Absorbing Head

Overall Length (cm)

Weight (gm)

Accuracy §

Repeatability

P20Y

0-20W

900-1250nm*

3000W/cm2

30 sec.

0.2

4.58 x 2.54 cm
(1.8" x 1")

22

89

+/-5%

+/-1.5%

P50Y

0-50W

900-1250nm*

3000W/cm2

20 sec.

0.5

4.58 x 2.54 cm
(1.8" x 1")

22

98

+/-5%

+/-1.5%

P100Y

0-100W

900-1250nm*

3000W/cm2

20 sec.

1

5.08 x 3.18 cm
(2"x1.25")

22

120

+/-5%

+/-1.5%

P100C

0-100W

8µ - 11µ

10,000W/cm2

20 sec.

1

5.08 x 3.18 cm
(2"x1.25")

22

120

+/-5%

+/-1.5%

P200Y

0-200W

900-1250nm*

2500W/cm2

20 sec.

2

5.08 cm dia.
(2" dia.)

22

157

+/-5%

+/-1.5%

P200C

0-200W

8µ - 11µ

7000W/cm2

20 sec.

2

5.08 cm dia.
(2" dia.)

22

157

+/-5%

+/-1.5%

P500Y

0-500W

900-1250nm*

2000W/cm2

20 sec.

5

5.08 cm dia.
(2" dia.)

22

183

+/-5%

+/-1.5%

P500C

0-500W

8µ - 11µ

4000W/cm2

20 sec.

5

5.08 cm dia.
(2" dia.)

22

183

+/-5%

+/-1.5%

P1000Y

0-1000W

900-1250nm*

1750W/cm2

20 sec.

10

6.35 cm dia.
(2.5" dia.)

22

287

+/-5%

+/-1.5%

P1000C

0-1000W

8µ - 11µ

2500W/cm2

20 sec.

10

6.35 cm dia.
(2.5" dia.)

22

287

+/-5%

+/-1.5%

P2000Y

0-2000W

900-1250nm*

1200W/cm2

20 sec.

20

7.62 cm dia.
(3" dia.)

22

522

+/-5%

+/-1.5%

P2000C

0-2000W

8µ - 11µ

1500W/cm2

20 sec.

20

7.62 cm dia.
(3" dia.)

22

522

+/-5%

+/-1.5%

P4000Y

0-4000W

900-1250nm*

900W/cm2

20 sec.

25

8.89 cm dia.
(3.5")

28

753

+/-5%

+/-1.5%

P4000C

0-4000W

8µ - 11µ

1100W/cm2

20 sec.

25

8.89 cm dia.
(3.5")

28

753

+/-5%

+/-1.5%

P10KY

0-5,000W
0-10kW

900-1250nm*

750W/cm2

20 sec.
10 sec.

50
100

8.89 cm dia.
(3.5")

28

1144

+/-5%

+/-1.5%

P10KC

0-5,000W
0-10kW

8µ - 11µ

900W/cm2

20 sec.
10 sec.

50
100

8.89 cm dia.
(3.5")

28

1144

+/-5%

+/-1.5%



Measuring Laser Performance with Analog Laser Power Probe, Analog Laser Measure


*Y type probe wavelength range
- These probes are calibrated at 8-11µ as well, but have a lower damage threshold for this range than the C type probes.  Calibration for any wavelength between 250nm – 2500nm is available upon request with an NIST certificate.

‡ Damage Threshold - Moving the probe during exposure will increase (up to double) the damage threshold compared to the numbers shown for a stationary probe. To achieve this increase, the head must be moved in a circular motion so that the laser beam does not strike any one area continuously for more than 1.5 seconds.

§ Accuracy and Exposure Time -  The accuracy and repeatability of the Power Probes partly depends on the accuracy of the exposure time. The average accuracy of exposures (hand held) has been found to be 0.2 seconds. This amounts to a 1% error for a 20 second exposure time. Many lasers are equipped with a shutter that can produce an exact time exposure.




Power Probe Carrying Cases

Hard Carrying Case for Analog Laser Power Probe, Analog Laser Measure - Measuring Laser Performance


PSCS Hard PlasticCase for P20 to P10K.

Soft Fabric Case also available.

Macken Instruments has cases to accommodate all Power Probes.

(sold separately)