MACKEN INSTRUMENTS, INC.

Near IR Display Statistics


DISPLAY CHARACTERISTICS

surface 1

surface 2

surface3

CW YAG & High Rep. Rate Nd

Saturated Display
(1) W/cm2

1000-8

--

--

High Resolution Display
(2) W/cm2

8-0.1

--

--

Minimum Power Density
(4) W/cm2

0.1

--

.0003

Depletion Energy Density
(3) J/cm2

--

--

2

Pulsed Nd

Saturated Display
(1) J/cm2

--

7-3

7-3

High Resolution Display
(2) J/cm2

--

3-.3

3-.3

GaAs Diode-- .9u

High Resolution Display
(2) mW/cm2

--

--

50-.1

Minimum Power Density
(4) mW/cm2

--

--

.02

Minimum Focused Power
mW

--

--

< .001

Depletion Energy Density
(3) mJ/cm2

--

--

80


SPECTRAL CHARACTERISTICS

surface 1

surface 2

surface3

Stimulation Wavelengths
micrometers

.7-1.6

.48-1.6

.53-1.6

Emission Wavelengths
micrometers

.5-.6

.48-.57

.54-.62

Excitation Wavelengths
micrometers

< .43

< .48

< .53

Resolution
lines/in.

> 300

> 50

> 50

Image Decay Time
seconds

.005

.1-200

.005-.05


DAMAGE LIMITS

display plate

beam probe

CW Damage Threshold
W/cm2

2000

2000

Pulsed Damage Threshold
(5) J/cm2

7

7

Maximum Average Power
W

200

40

Maximum Intermittent Power
W

1000

100


<-Back a page
Go to Table of Contents